EQ Window, Target Matching, and Filter Design
Model filters, match a response to a target, and predict time-domain results before sending DSP coefficients.
What this is for
The EQ window is where REW models filters, matches a response to a target, and predicts the result. It helps you design cuts and boosts that are physically realizable and acoustically sensible.
Concrete steps
Outputs and interpretation
| Graph/Panel | What it tells you |
|---|---|
| Filter Adjust | Measured, predicted, target, filters, and filters+target responses. |
| EQ Filters panel | Filter types, frequencies, gains, Q/bandwidth, headroom. |
| Predicted Waterfall | Predicted time-domain effect. |
| Predicted Impulse/Phase/Group Delay | Predicted time/phase behavior. |
| Modal Analysis | Resonances and T60. |
| Pole-Zero plot | Poles and zeroes of resonances and filters. |
Worked example: House curve with +6 dB at 20 Hz
Make a full-range measurement. Open EQ → Target Settings. Choose Full Range. Add a room curve with LF Rise start 20 Hz, end 80 Hz, slope +6 dB. Or load a house curve file:
20 6.0
80 0.0
Set Target Level automatically. Set Match Range 20–200 Hz, max boost 0, allow narrow filters below 200 Hz. Press Match Response to Target. Inspect Filter Adjust — the target should include the house curve. Check predicted response and headroom. Send filters or measure with filters.
Common mistakes
- EQing dips instead of peaks.
- Too much boost and no headroom.
- Using filters to fix a level difference.
- Narrow filters above the modal range.
- Not using variable smoothing before matching.
- Ignoring predicted time-domain results.