Lesson 8

Alignment, Overlays, Averaging, and Trace Arithmetic

Compare measurements, average multiple positions, align subwoofers/mains, and combine traces.

What this is for

These tools let you compare measurements, average multiple positions, combine traces, and align speakers/subs. They are essential for crossover integration, spatial averaging, and correcting measurement data.

Concrete steps

0 of 11 steps completed (0%)

Outputs and interpretation

OutputWhat it tells you
Overlay graphsMultiple measurements together.
Averaged traceRepresentative response.
Arithmetic resultCombined or corrected response.
Aligned sumPredicted summed response.
IACCInter-aural cross correlation.

Worked example: Sub/main crossover alignment

Place the mic at the listening position. Use a timing reference. Measure the left main speaker alone, the subwoofer alone, and both together. Open All SPL and select the main and sub measurements. Open Alignment Tool. Choose phase or impulse alignment mode. Set the cursor near the crossover frequency, e.g. 80 Hz. Adjust delay, gain, and polarity of the sub. Use Aligned sum to preview the combined response. Check SPL & Phase for a smooth crossover. Apply the delay/polarity settings in the AV processor and re-measure both together.

Common mistakes

Check your understanding

1. Vector average requires:
2. Trace arithmetic division has:
3. Alignment tool impulse mode cross-correlates: